Circuit breaker (CB):
CB is nothing but a special kind
of switch, which can be operated manually
and automatically. In power system network, the load is increasing day by day. All
power system equipment was design for a specific range of current. If system
current (current following through the
equipment) is increased beyond this
range, equipment may damage and cost of this equipment is high. So, it
important to protect the equipment and CB plays important role in protection
engineering.
When a fault occurs in the
system, an excessive amount of current will flow through the system. This
current will thousand times higher than the rated current, that will depend on the type of fault. In the overload
condition, current will increase, but in this case, current will be a few times higher than the rated current. The
equipment or the network of the power system which we want to protect that will
be connected in series with CB and relay. CB cannot sense the fault, the relay is used to sense the fault and if the current is
increased from pre-specified value, it will give a signal to CB and CB
will operate. This is how fault protection scheme works in the power system.
Working of CB:
CB has two arms (contacts); fixed
arm and moving arm. If these contacts are in contact (ON) that means the circuit is close and if these contacts aren’t
in contact (OFF) that means the circuit is
open. Contacts will be ON or OFF, that depends on the operating condition of
the system. CB is ON in normal condition
and it will manually or automatically OFF in abnormal conditions. A handle
connects with the moving arm and this handle is
used for the manual operation of CB.
Working of CB looks easy, but it
is very difficult in case of higher voltage (in kV). When CB is turned on or
off, at that time spark occurs between the contacts. The reason behind the
spark is a very high potential difference between the arms. One arm has zero
voltage and another arm has rated voltage (kV) at a time of switching. This
potential difference is sufficient to ionize the air between the arms and
create a spark between the two contacts. Very high amount of current will flow
through the contacts and this current is sufficient to damage the contacts. Arc
quenching medium is used the contacts to
avoid this condition. When CB is turn ON or OFF, arc quenching medium comes to the contacts and quench the arc. SF6,
transformer oil, air etc are used as a quenching medium. CB can classify
according to arc quenching medium.
Classification of CB:
According to arc quenching medium,
classification of CB is as below;
1)
SF6
CB: A CB which uses SF6 (sulphur
hexafluoride) as an arc quenching medium, that is known as an SF6 circuit breaker. SF6 CB is advanced and
most used CB compare to another CB. SF6 has very good insulating property and
very high electronegativity. When an arc occurs,
free electrons are produced because of ionization process. These free electrons are
colliding with SF6 gas molecules. SF6 molecules have
a tendency to absorb the free
electrons. SF6 has very good heat transfer capability. The high temperature is produced
due to arc and SF6 has the ability to
reduce the temperature. SF6 is 100 times more
efficient arc quenching medium compared to air. This CB is used for the voltage range of 33 kV to 800 kV. The disadvantage of this CB is that SF6 has a
global warming potential that is 23,900 times worse than CO2.
2)
Oil
CB: Oil is used as a dielectric
medium in this type of CB. This oil is known as transformer oil or mineral oil.
This type of CB is a very oldest type of
CB and rarely used in present power system network. The oil has good dielectric
property and acts as the best liquid insulator. The fixed contact
and moving contact are immersed in the
insulating medium of mineral oil. When circuit breaker turns ON and OFF, the arc will initialize between the contacts. The
oil is vaporized and decompose in
hydrogen gas. This gas is produced in
form of bubbles and these bubbles are produced
around the arc and prevent restricting of
the arc after current reaches zero
crossing of the cycle. Two types of oil circuit breakers are available; bulk
oil circuit breaker and minimum oil circuit breaker. Oil CB is used for the voltage range of 1 kV to 300
kV.
3)
Air
CB: This type of CB uses atmosphere air as an arcing medium so this CB is
known as air circuit breaker or air blast circuit breaker. This CB is not used for very high voltage. It used for low or medium voltage level. This CB is
preferable compared to oil CB because this CB is safer. There are chances for oil blasting which is very dangerous. In developed countries, air circuit
breaker is used instead of oil CB.
Working principle of air CB is different compared
to another CB. It creates an arc voltage for interruption of the arc. Arc voltage is a minimum voltage required to maintain the arc.
·
Arc voltage can be increased by cooling of arc plasma.
·
Arc is a divide
into a number
of the series path.
·
By increasing the length of the arc.
Two types of air
blast CB are available; plain air CB and air blast CB.
4)
Vacuum
CB: Vacuum is used as a dielectric
medium, so this type of CB is known as vacuum CB. This CB technology is not
fully developed. The performance of CB is depending on the material used for
the contacts. Generally, copper/chrome is
used for good performance. The vacuum has
very good dielectric properties. The dielectric strength of vacuum is eight
times higher than air and four times higher than SF6 gas. When breaker
operates, the production of an arc is due to the ionization of metal ions. The
metallic vapor produces electron and ions during the arc. So, the arc will be
extinguished quickly. Vacuum CB is used
in the distribution network and voltage range is 22 kV to 66 kV. Generally,
this CB is used in a rural area.
Classification according to voltage level,
1)
Low
voltage CB: This type of CB is used
in the domestic, commercial and
industrial application. The voltage level around 1 kV is considered as a low voltage CB. It includes MCB, MCCB, and RCCB.
MCB stands for the miniature
circuit breaker. MCB is an electromechanical device. MCB provides protection
against overcurrent and overload. When a fault
occurs in the system, it will produce a high amount of current. This condition is known
as overcurrent. If the load is increased, system current will increase.
This condition is known as overload. MCB can operate manually and it will operate
automatically in case of overload and overcurrent. In normal condition, a force
produced by a current caring coil is less
than the force produced by the spring. In
overcurrent condition, the force of
current caring coil is greater than the force of spring and it will responsible
for the trip. This is called as magnetic
tripping.
In case of overload, bimetallic strip is used. The displacement
occurs in bimetallic strip due to overload. This tripping is called thermal
tripping.
MCCB stands for Moulded
Case Circuit Breaker. MCCB is used for 250 A to 800 A current.
2)
High
voltage CB: High voltage CB is not used in the industrial, residential and commercial application. This type of CB
is used in the range of kV. Generally, high voltage CB is used in power system
transmission and distribution. In power system network, CB is used to isolate
faulty part from rest of the healthy
system.
For example, a 220-kV transmission line is connected to power system network and fault occur in this
line for any reason. So, it is necessary
to isolate this line from the rest of the network. Two CB are connected at both
ends of the transmission line and in this
condition both CB open and isolate the faulty line.
Nice article!
ReplyDeleteI have vintage porcelain insulators for sale, but not industrial, just collectible!
Amazing content with proper examples and I like your Article thanks for shairing The Wilo Hidrainlift Waste Water Pump is designed to pump sewage from a dishwasher or washing machine. The device is capable of pumping sewage up to 60 °C. and Aflexwn is provide A Load Bank Rental & Sales can make you aware about performance of your equipment like generator, motor, etc at full load &/or partial load